Mammography Flat Panel Detector

التصنيفات: ,

الوصف

Mammo 1012C

  • | 235 × 290 active area |
  • | Reliable AED function |
  • | Compact design for easy integration |
  • | Compatible with old AEC module |

The Mammo1012C is a digital FPD detector with Amorphous Silicon TFT sensor technology. It is designed with the compact outline in order to retrofit the analog mammography system to digital. The detector provides AED function  via the specialized sensor to detect the X-ray for activing the FPD, and is also compatible with the existed AEC function of the analog mammography system. Mammo1012C only supports FFDM applications.

Cassette size a-Si Mammography Detector:

  • Detector Technology                                                                               Amorphous Silicon
  • Scintillator                                                                                                 CsI
  • Active Area (mm)                                                                                     235 × 290
  • Pixel Matrix                                                                                               2762 × 3408
  • Pixel Pitch (μm)                                                                                        85
  • Spatial Resolution (lp/mm)                                                                       6
  • AD Conversion (bit)                                                                                  16
  • Dynamic Range (dB)                                                                                >76
  • Chest Wall Distance (mm)                                                                        ≤ 3
  • Data Interface                                                                                         GigE
  • Trigger Mode                                                                                           Software / AED
  • Dimensions (mm3)                                                                                   327 × 254.5 × 14
  • Weight (kg)                                                                                               ≈ 1.3
  • Power Dissipation (W)                                                                              ≈ 18
  • Operating Temperature (℃)                                                                    10 ~ 40
  • Storage & Transport Temperature with Package (℃)                            -10 ~ 55
  • Operating Humidity (% RH)                                                                10 ~ 90 (Non-Condensing)
  • Storage & Transport Humidity with Package (% RH)                         10 ~ 95 (Non-Condensing)

                                                                                                                               

 